CMDE opens public consultation on 10 draft technical review points for Class II IVD medical devices

Time:2026-11-13

The Center for Medical Device Evaluation of the National Medical Products Administration issued a notice on November 12, 2026, opening public consultation on 10 draft technical review points for Class II in vitro diagnostic medical devices, including the draft technical review point for phosphorus determination reagents.


The drafts cover phosphorus determination reagents, growth hormone detection reagents, aldosterone detection reagents, angiotensin-converting enzyme detection reagents, free fatty acid determination reagents, apolipoprotein E determination reagents, mycobacterial culture additives, anti-sperm antibody detection reagents, mycophenolic acid determination reagents, and Staphylococcus identification reagents. These review points are intended to standardize technical review and provide technical reference for applicants preparing registration dossiers. According to the annexes, each review point sets out specific requirements on scope of application, methodology, sample types, product technical requirements and performance indicators, analytical performance evaluation, stability, reference intervals/positive cut-off values, clinical evaluation pathways, and key points for instructions for use. For example, the phosphorus determination reagent review point applies to in vitro quantitative determination of phosphorus in human serum, plasma, and urine based on spectrophotometry, with management class II and classification code 6840-14-14013; its analytical performance focuses on trueness, precision, LoB/LoD/LoQ, analytical specificity, linearity and reportable range, reagent blank, and analytical sensitivity. The growth hormone detection reagent review point is based on antigen-antibody reactions using chemiluminescence immunoassay, electrochemiluminescence, etc., covers serum, plasma, and whole blood, refers to YY/T 1593, and uses the national standard substance for human growth hormone immunoassay. The aldosterone detection reagent review point covers immunoassays and LC-MS/MS, with serum, plasma, whole blood, and urine as possible sample types; it does not apply to colloidal gold-labeled qualitative/semi-quantitative reagents or radioisotope-labeled radioimmunoassay/immunoradiometric assay reagents, and mentions the national standard substance for aldosterone in frozen human serum and YY/T 1962-2025. The mycophenolic acid determination reagent review point covers chemiluminescence, homogeneous enzyme immunoassay, fluorescence immunochromatography, immunoturbidimetry, and LC-MS/MS, and is used for therapeutic drug monitoring of mycophenolic acid. The annexes also generally emphasize studies on sample stability, applicable sample types, calibrator traceability and control material assignment, trueness, precision, detection capability, analytical specificity, linearity/measuring interval/reportable range, as well as real-time, in-use, and transport stability.


Comments should be submitted using the designated comment form to the designated contact by December 15, 2026. If you are preparing a China registration dossier for relevant IVD products, it is worth reviewing the official notice and assessing.