On October 28, 2026, the National Medical Products Administration issued the Notice on Issuing Four Inspection Guidance Principles, Including the Guidance Principle for Inspection of Sterile Medical Devices under the Medical Device Manufacturing Quality Management Specification (Document No. Guo Yao Jian Xie Guan [2026] No. 16). The newly revised Medical Device Manufacturing Quality Management Specification will take effect on November 1, 2026.
To better guide production inspections for sterile, implantable, in vitro diagnostic reagent, and custom-made denture medical devices, NMPA organized the revision and formed four inspection guidance principles: the Guidance Principle for Inspection of Sterile Medical Devices, the Guidance Principle for Inspection of Implantable Medical Devices, the Guidance Principle for Inspection of In Vitro Diagnostic Reagents, and the Guidance Principle for Inspection of Custom-Made Dentures under the Medical Device Manufacturing Quality Management Specification.
The notice’s annexes contain four inspection item lists. Based on the importance of each clause of the Specification and the corresponding appendices in the quality management system and the degree of quality and safety risk caused by non-compliance, the annexes integrate and align the content of the appendices with the Specification, convert them into inspection items, and classify them into three levels: critical items (***), major items (**), and general items (*). Specifically, custom-made denture inspection items total 190, including 38 critical items, 88 major items, and 64 general items; in vitro diagnostic reagent inspection items total 212, including 42 critical items, 93 major items, and 77 general items; implantable medical device inspection items total 220, including 43 critical items, 97 major items, and 80 general items; sterile medical device inspection items total 216, including 41 critical items, 95 major items, and 80 general items. Inspection types and result determination follow the Guidance Principle for Inspection under the Medical Device Manufacturing Quality Management Specification.
These four inspection guidance principles will take effect on November 1, 2026, and the previous on-site inspection guidance principles for sterile, implantable, in vitro diagnostic reagent, and custom-made denture medical devices issued by the former China Food and Drug Administration will be repealed at the same time. Starting November 1, 2026, when drug regulatory authorities conduct relevant production license verification and post-market supervision inspections, inspection results will be determined in accordance with the corresponding newly revised guidance principles.
For affected companies, this is an important compliance transition point. It is advisable to promptly review quality management systems, inspection items, and risk-level requirements against the new guidance principles and their annexes, and to prepare for the transition in system documents, site management, and personnel training.